Delimbe seeder T17e 400L + 3 points hitch & 20' foldable seeding bar
The Delimbe T17 air seeder is a multi-
It is equiped with a 20' manual foldable seeding bar frame mounted with 8 dispersions plates and a category two 3 points hitch.
T17 TECHNICAL SPECIFICATIONS
400 liter tank capacity (11.35 bushels)
8 outlet air distributor
Dimensions: 51 inch wide
43 inch high
51 inch deep
Blower pipe: 30mm diameter
Supply voltage:12 volts motor
Two control systems are available:
1. Standard includes control box with on/off and speed variation for calibration.
2. Additional option B: Self contained GPS control system
FITTING AND ELECTRICAL CONNECTION
If sufficient power is not provided from the socket within the tractor cab, then source power direct from the tractor battery and protect with a 30 amp fuse.
Three types of seed rotor are include with the seeder depending on the size of seed to be sown. Green for small seeds, stainless steel (yellow) for larger seeds and red for large seeds and grass seed.
CALIBRATION
All applicators are calibrated in kilogrammes per hour.
The calibration calculation is:
Working width(meter) x forward speed (kilometer/hour) which gives you hectares per hour. Multiply the hectares per hour by the desired seed rate and the result is the kilogrammes per hour. Look in the settings table for the chosen rotor and the kg/hr has a number which relates to the dial setting on the control box.
Example:
A Delimbe T18 300L mounted on a 3 metre cultivator seeding alfalfa with a green rotor traveling at 10km/hour at a seed rate of 4kg/hectare:
3 metre x 10 km/hr = 30,000 m2 = 3.0 ha/hour
3 ha/hr x 4 kg/ha = 12 kg/hr
12 kg/hr in the green rotor settings table is between dial setting 8 or 9 on the dial. Now set the dial between 8 and 9 on the control box dial.
Now check the calibration setting. Put the ends of the pipes in a bucket or bag, run the applicator for one minute, collect the seed, weigh it and multiply by 60 to check the flow rate per hour. If necessary adjust the control box variator up or down and run the test again to check the flow rate.